Waterproof concrete basement

Waterproofing Overview

The waterproofing regime on this project had to include a dual-protection system to satisfy the requirements of the warranty provider. Midland Tanking was the designer and installer for both systems.

Primary System

Type B – Waterproof concrete integral protection

All external walls, all concrete slabs (ground and basement floor) were cast with concrete including a waterproof additive. The steel reinforcing within this structure was designed to reduce the cracking to less than 0.3mm, also providing integral protection. All construction and day joints have a crystalising waterproofing slurry and an expanding waterbar applied to them to waterproof natural weak points.

Secondary System

Type C – Drained cavity protection

With the primary waterproof concrete system providing most of the protection, the secondary system was installed. At the base of all external walls a recessed concrete channel was created within the slab. All walls and the floor were lined with a cavity drainage membrane (CDM). These membranes were linked to sump chambers via the recessed perimeter channels. Within the sump is two pumps and a high-level alarm. This system is designed to catch any water that is not stopped by the primary system and discharge it automatically. Flushing and maintenance points were installed to allow future servicing of the system. The front and rear lower sections are linked with a underground pipe.

Both waterproofing systems were designed by Structural Surveyors in Structural Waterproofing (CSSW) in accordance with BS8102:2009

All waterproofing materials were supplied by Triton Systems Ltd

Project Details

Categories:
Client: Mercia Design & Build
Location: Stafford
Surface Area: 213 square metres
Completed: 2022
Architect: 2022
Link: Visit project

Click below to contact us and get a quote